Skip to content
Travel & Tech

Verified & updated:

Asia travel plug adaptor & voltage guide

Asia spans ten IEC socket standards and voltages from 100 V in Japan to 230 V in India, Singapore, and South Korea. Select your exact stops to build one reliable packing kit.

230 V · 50 Hz
Classic itineraries:
Countries on your trip (5)

Multi-stop adaptor strategy

Universal adaptor or 2+ plugs needed

Your 5 selected stops span incompatible socket standards (Type A, B, F, O). Pack a certified universal travel adaptor (BS 8546 / fused) or dedicated country adaptors for each zone.

Earthing & socket traps

Local socket & earthing traps

One or more stops on your route feature recessed sockets, unearthed 2-pin dominance, or earth-loss traps (see details below). Do not rely on cheap 2-pin blocks for earthed gear.

Voltage across your stops

Mixed voltage grids (100–230 V)

Your selected stops cross both 100–127 V and 220–240 V grids (or include a dual-voltage country). Stick strictly to 100–240 V, 50/60 Hz dual-voltage devices across the entire trip.

Wall sockets to cover on your selected route

Amber marks the earth pin or earthing clip; charcoal marks live and neutral contacts.

  • Most everyday outlets in Japan are 2-pin Type A; 3-pin Type B receptacles are rare outside newer offices, bathrooms, and heavy-appliance circuits.
  • Type G (BS 1363) outlets use shuttered live holes opened by the top earth pin and require a built-in fuse inside the plug.
  • Thailand’s official standard is 3-pin Type O (TIS 166-2549). Many hybrid sockets accept flat (Type A/B) and 2-pin round (Type C) plugs, but European Type E/F plugs lose their earth connection without a grounded adapter.

All 35 destinations in Asia: plugs, voltage & adaptor check

Every country and territory in Asia listed with official IEC wall sockets, nominal voltage, frequency, and live adaptor status from your selected departure country.

Country / Territory Wall Sockets Voltage & Hz From Your Departure
Afghanistan C, F 230 V · 50 Hz Plug adaptor required
Armenia C, F 230 V · 50 Hz Plug adaptor required
Azerbaijan C, F 230 V · 50 Hz Plug adaptor required
Bangladesh A, C, D, G 220 V · 50 Hz No adaptor needed
Bhutan C, D, F, G, M 230 V · 50 Hz No adaptor needed
Brunei G 240 V · 50 Hz No adaptor needed
Cambodia A, C, G 230 V · 50 Hz No adaptor needed
China A, C, I 220 V · 50 Hz Plug adaptor required
Georgia C, F 230 V · 50 Hz Plug adaptor required
Hong Kong G 220 V · 50 Hz No adaptor needed
India C, D, M 230 V · 50 Hz Plug adaptor required
Indonesia C, F 230 V · 50 Hz Plug adaptor required
Japan A, B 100 V · 50/60 Hz Plug adaptor required
Kazakhstan C, F 230 V · 50 Hz Plug adaptor required
Kyrgyzstan C, F 230 V · 50 Hz Plug adaptor required
Laos A, B, C, E, F 230 V · 50 Hz Plug adaptor required
Macau G 220 V · 50 Hz No adaptor needed
Malaysia G 240 V · 50 Hz No adaptor needed
Maldives D, G, J, K, L 230 V · 50 Hz No adaptor needed
Mongolia C, E 230 V · 50 Hz Plug adaptor required
Myanmar C, D, F, G 230 V · 50 Hz No adaptor needed
Nepal C, D, M 230 V · 50 Hz Plug adaptor required
North Korea C, F 230 V · 50 Hz Plug adaptor required
Pakistan C, D, G, M 230 V · 50 Hz No adaptor needed
Philippines A, B, C 220 V · 60 Hz Plug adaptor required
Singapore G 230 V · 50 Hz No adaptor needed
South Korea C, F 220 V · 60 Hz Plug adaptor required
Sri Lanka D, G, M 230 V · 50 Hz No adaptor needed
Taiwan A, B 110 V · 60 Hz Plug adaptor required
Tajikistan C, F, I 230 V · 50 Hz Plug adaptor required
Thailand A, B, C, O 230 V · 50 Hz Plug adaptor required
Timor-Leste C, E, F, I 230 V · 50 Hz Plug adaptor required
Turkmenistan B, C, F 230 V · 50 Hz Plug adaptor required
Uzbekistan C, E, F 230 V · 50 Hz Plug adaptor required
Vietnam A, C 220 V · 50 Hz Plug adaptor required

East Asia hub hopping: five neighbors, four completely different outlet standards

Even a short East Asia itinerary crosses both plug standards and voltage tiers at every border:

Japan (100 V · 50/60 Hz) & Taiwan (110 V · 60 Hz)

Both use flat Type A/B blades, but over 90% of Japanese hotel wall sockets are 2-pin ungrounded Type A (blocking 3-prong laptop bricks) and Japan’s 100 V grid splits 50 Hz (Tokyo) vs. 60 Hz (Osaka/Kyoto).

South Korea (220 V · 60 Hz · Types C & F)

Uses deeply recessed European Schuko Type F sockets — completely incompatible with Japanese/US flat blades and Hong Kong Type G.

Hong Kong & Macau (220 V · Type G) vs. Mainland China (220 V · Types A, C, I)

Hong Kong and Macau standardize on shuttered British Type G. Mainland China wall plates typically combine ungrounded Type A/C on top with angled 3-pin Type I below at 220 V / 50 Hz.

India, Nepal & Sri Lanka: why standard universal sliders fail on Type D and Type M

India, Nepal, and Sri Lanka run at 230 V / 50 Hz using compact 3-round-pin Type D (5 A) for wall chargers and oversized Type M (15 A) for heavy appliances (Sri Lanka also mixes British Type G).

Most 4-slider universal adapters only expose Types A, C, G, and I — completely omitting Type D and Type M. While thin Type C pins loosely enter some older Indian Type D sockets, they make poor contact and fall out easily; pack a dedicated Type D adapter (or Type D + G if combining Sri Lanka/Maldives).

Frequently asked questions

Yes — a compact universal adapter with A, C, G, and I sliders covers Japan (2-pin Type A), South Korea (Type C), Hong Kong (Type G), and Mainland China (Type A/I). Just confirm your devices are 100–240 V because voltages jump between 100 V (Japan) and 220 V (Korea/HK/China).

How this works

Evaluates international plug compatibility across 221 countries and territories and all 15 IEC plug types (A–O) by separating physical pin insertion, safety grounding continuity, and nominal single-phase grid voltage/frequency tolerances.

Physical plug fit
Checks every home plug standard against the destination’s wall sockets using IEC physical fit rules (for example, Type C Europlug fits E, F, H, J, K, L, N, and O; modern CEE 7/7 fits E and F, but is blocked in older Italian Type L sockets).
Grounding continuity
Flags destinations where grounded 3-pin receptacles are rare (Japan: >90% 2-pin Type A), where mechanical entry loses earth (Type E/F in Danish Type K or Thai hybrid sockets), or where grounded origin plugs lack a matching earthed socket.
Voltage & frequency check
Marks grids compatible only when nominal voltage differs by ≤ 15 V with matching frequency (50 Hz vs. 60 Hz); flags 16–30 V gaps (such as 120 V vs. 100 V) as heating/motor caution, and requires 100–240 V label verification for larger gaps or dual-voltage countries (such as Brazil 127 / 220 V).
  • Country socket lists reflect standard residential and hotel wall outlets per IEC World Plugs and national wiring codes, excluding obsolete theater or industrial-only sockets.
  • Dual-voltage destinations (such as Brazil, Cuba, Belize, and Bolivia) always trigger device-label verification for international travelers even if one regional voltage resembles home power.

Sources & standards

More Travel & Tech tools

All tools

Related tools